Description
产品规格:
– 型号 200-530-025-014
– 型号:200-530-025-014 200-530-111-013
200-530-025-014特征
16个动态通道和4个转速通道
每个动态通道和每个双通道最多20个处理输出(每个xmc 16 12个)
利用异步(固定频率)或同步(顺序跟踪)采样在所有通道上同时采集数据
24位数据采集,高信噪比数据处理,高分辨率FFT高达每500 ms 6400行
专为与VibroSight软件配合使用而设计
200-530-025-014燃烧状态监控模块用于监测燃烧的状态,是燃烧安全系统的重要组成部分。
燃烧状态监控模块的工作原理是利用传感器采集相关参数,例如火焰的亮度、燃烧时的声音等,再通过数据处理和分析,判断出燃烧的状态,从而对燃烧过程进行监控,如果发现异常或危险,会立即发出警报。
燃烧状态监控模块的应用范围很广,不仅可用于各种燃烧设备,例如锅炉、窑炉等,也可以用于监测燃烧安全。
【英文介绍】
Product parameters:
Model: VM600 IOC16T
Product Number: 200-565-000-013, 200-565-101-013
Working voltage: 24VDC
Operating temperature: -20℃~+70℃
Vibration measurement range: 0~50mm/s
Temperature measurement range: -50℃~+150℃
Communication interface: Modbus RTU, Profibus DP, Ethernet/IP
Vibro-Meter-IOCT16T 200-565-000-013 Control processor A dedicated modular unit with a microcomputer or microprocessor as the core to complete the control logic and control algorithms.
In a computer system, the control processor and the processor are the two basic components. The controller is usually used to control various hardware and software resources of the computer, and can coordinate and manage each component through command and control signals. The processor is the core component of the computer, responsible for executing instructions, processing data, controlling various hardware and performing various tasks required by the operating system.
【其他型号推荐】
- Vibro-meter 200-510-041-021 200-510-111-021 VM600 MPC4
- Vibro-meter 200-510-071-113 200-510-111-034 VM600 MPC4
- Vibro-meter 600-003 620-001-001-116 VM600 XMV16
- Vibro-meter 200-560-000-016 200-560-101-015 VM600 IOC4T
- Vibro-meter 200-560-000-018 200-560-101-015 VM600 IOC4T
- Vibro-meter 620-002-000-113 620-003-111-112 VM600 XIO16T
- Vibro-meter 200-566-000-012 200-566-101-012 VM600 IOCN
- Vibro-meter VM600-ABE040 204-040-100-011
- Vibro-meter VM600-ABE040 204-040-100-011
- Vibro-meter 200-595-100-014 200-595-072-122 VM600 CPUM
- Vibro-meter 600-003 620-001-001-116 VM600 XMV16
- Vibro-meter 620-002-000-113 620-003-111-112 VM600 XI016T
- Vibro-meter 200-560-000-016 200-560-101-015 VM600 IOC4T
- Vibro-meter 200-560-000-113 200-560-101-017 VM600 IOC4T
- Vibro-meter 200-566-000-012 200-566-101-012 VM600 IOCN